MITPC3K (10-12KW)
MITPC3K series is a three-phase power frequency off grid integrated photovoltaic inverter, with a variety of working mode selection, perfect protection function, advanced DSP and control technology, higher stability and reliability of the system, but also can realize the three-phase free networking function. To maximize the energy generated by the photovoltaic system to the load; If there is excess energy used to charge the battery, there is still excess energy will be sold into the power grid, widely used in household power generation system, communication base station, border defense, highway and bridge construction.
Category:INVERTER
Category:ON Grid inverter
Contact Us
-
Product Description
-
Parameter
-
Features:
· Smart LCD setting(Working modes, Charge Current, Charge Voltage, etc.)
· Built-in MPPT 180A solar charge controller
· MPPT Efficiency max 98%
· Combining solar system, AC utility, and battery power source to supply continuous power
· Multiple operations: basic Grid-tie, Off-Grid, Grid-Interactive
· Support CAN, RS485 monitoring function
-
MODEL
MITPC3K
Rated battery voltage
48VDC
Inverter output
output rating
10000W
12000W
discharge waveform
pure sine wave
Rated output voltage
230 VAC (P-N) / 400 VAC (P-P)
rated output current
14.3A / Road
17.4A / Road
Rated output frequency
50 Hz / 60 Hz
Wavveform distortion rate (THDI) linear load
Off-grid 2%; power grid discharge 3%; power grid power supply 3%
Inverse peak efficiency
≥ 93%
overload capacity
100% <Load 110%, 30 min; 110% <load 125%, 1 min; 125% <Load 150%, 30s; load <150%, 10s; short circuit for 5s
AC input
AC input the maximum current
26.0A / Road
34.8A / Road
rated frequency
50Hz / 60Hz
AC Input voltage range
The default value is 186Vac ~ 253Vac; narrow 174Vac ~ 272Vac; wide 95Vac ~ 272Vac
cell
Battery type
Lithium batteries or lead-acid batteries
rated voltage
48VDC
Low pressure protection point
Charger 34.0VDC; inverter 40.0VDC
Absorb charging voltage
50.0VDC
Then float charge voltage
54.8VDC
floating charge voltage
57.2VDC
Solar Chargers & AC Chargers
The PV maximum open-circuit voltage
145VDC
Maximum solar charging current
60A / Road
Maximum AC, charging current
60A / Road
80A / Road
Maximum charging current
120A / Road
140A / Road
rating of machine
way to install
Vertical vertical
Machine Dimensions (W * H * D) (mm)
392*828*629
Package Dimensions (W * H * D) (mm)
513*1031*700
net weight (kg)
133
140
rough weight (kg)
128
160
other
communication interface
RS485 / CAN bus
Use ambient temperature
0℃ ~ +50℃
levels of protection
IP20
Operating humidity range
0~90% Relative humidity (no condensation)
height
≤ 2000m